Otherwise, on the command of G32, the hotend leaves for endostops and the work is interrupted.
![cetus3d calibration cetus3d calibration](https://www.jackenhack.com/wp-content/uploads/2018/02/cetus3d-remove-screws-z-axis-580x773@2x.jpg)
If you set this setting to a height, the compensation will start to be applied less and less (linearly) until "height_limit" is reached.
Cetus3d calibration full#
_start 0.5 # Compansation normally is applied for all heights, with full power. _by_two_corners false # G29/31/32 will not work without providing XYAB parameters: XY - start point, AB rectangle size from starting point. _readable true # Human readable formatting of probe table Probe where to move to in Z before it probes, this should be around 5-10mm above the bed _height 5 # The initial height of the probe lift above the table, mm. true # True = When you start the printer, the table is loaded from the file _offsets 20,0,0 # Offset of the probe in relation to the nozzle, mm FALSE, If you are not using all 3 endstops _home false # This can be set if you want the leveling strategy to home before probing. _y_size 5 # The number of points along the Y axis for the case if X! = Y. _x_size 5 # The number of points along the X axis for the case if X! = Y. # 5 # Number of points on each of the axes. true #The strategy must be enabled in the config, as well as the zprobe module. What am I missing here? What am I doing wrong? I printed without leveling and with leveling and there’s no difference.
Cetus3d calibration manual#
I tried flashing the latest firmware, an older firmware, changing the leveling strategy, many codes of leveling, rewriting from scratch the config file to match the firmware, following the zprobe manual over and over again, but it all boils down to this: It does the calibration nicely and write the conclusions in the machine control terminal, but all the prints look the same, and it is evident that the calibration is not taken into account. I tried G29, G32, both of them with 3 point calibration, now G31 is the latest. _by_two_corners true # Two point calibration Mm_per_line_segment 1 # necessary for cartesians using rectangular-grid _limit 1 # no compensation to apply after this point (optional) _start 0.5 # compensation decrease point (optional) _height 10 # will move to Z10 before the first probe false # If the saved grid is to be loaded on boot then this must be set to true _offsets 0,0,0 # Optional probe offsets from the nozzle or tool head 5 # The size of the grid, for example, 7 causes a 7x7 grid with 49 points.
![cetus3d calibration cetus3d calibration](https://static.wixstatic.com/media/66cf39_462ea53d4e144055a5ee9091719ecc63~mv2_d_5620_3747_s_4_2.jpg)
true # The strategy must be enabled in the config, as well as the zprobe module.